﻿<?xml version="1.0" encoding="UTF-8"?>
<rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>IL COMPUTER BLOG &#187; Intel</title>
	<atom:link href="http://www.ilcomputer.com/wordpress/tag/intel/feed/" rel="self" type="application/rss+xml" />
	<link>http://www.ilcomputer.com/wordpress</link>
	<description>Pillole di computer</description>
	<lastBuildDate>Thu, 14 Jul 2011 16:15:27 +0000</lastBuildDate>
	<language>en</language>
	<sy:updatePeriod>hourly</sy:updatePeriod>
	<sy:updateFrequency>1</sy:updateFrequency>
	<generator>http://wordpress.org/?v=3.3.1</generator>
		<item>
		<title>STOP:0x0000000A on Windows 2003 install</title>
		<link>http://www.ilcomputer.com/wordpress/2011/06/15/stop0x0000000a-on-windows-2003-install/</link>
		<comments>http://www.ilcomputer.com/wordpress/2011/06/15/stop0x0000000a-on-windows-2003-install/#comments</comments>
		<pubDate>Wed, 15 Jun 2011 20:15:16 +0000</pubDate>
		<dc:creator>Alessandro Spiandore</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[software]]></category>
		<category><![CDATA[0x0000000A]]></category>
		<category><![CDATA[2003]]></category>
		<category><![CDATA[32bit]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[IRQL_NOT_LESS_OR_EQUAL]]></category>
		<category><![CDATA[Server]]></category>
		<category><![CDATA[Windows]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=373</guid>
		<description><![CDATA[<p>Problema: Quando si installa Windows 2003 Server 32bit senza nessun Service Pack integrato su di alcune schede madri si può avere come risultato: STOP:0X0000000A (0X00000010,0X00000002,0X00000000,0X805527BC)  e IRQL_NOT_LESS_OR_EQUAL su una bella schermata blu. (BSOD). Soluzione: Bisogna disabilitare (solo durante l&#8217;installazione) l&#8217;opzione &#8220;Core Multi-Processing&#8221;. Al termine dell&#8217;installazione ovviamente si consiglia d&#8217;installare l&#8217;ultimo service pack disponibile con i relativi [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Alessandro Spiandore <a href="http://www.ilcomputer.com/wordpress/2011/06/15/stop0x0000000a-on-windows-2003-install/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2011/06/15/stop0x0000000a-on-windows-2003-install/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Aggiungere network driver su Symantec Backup Exec System Recovery (BESR)</title>
		<link>http://www.ilcomputer.com/wordpress/2011/04/12/aggiungere-network-driver-su-symantec-backup-exec-system-recovery-besr/</link>
		<comments>http://www.ilcomputer.com/wordpress/2011/04/12/aggiungere-network-driver-su-symantec-backup-exec-system-recovery-besr/#comments</comments>
		<pubDate>Tue, 12 Apr 2011 20:28:23 +0000</pubDate>
		<dc:creator>Alessandro Spiandore</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[software]]></category>
		<category><![CDATA[2010]]></category>
		<category><![CDATA[82578]]></category>
		<category><![CDATA[82578DC]]></category>
		<category><![CDATA[Backup]]></category>
		<category><![CDATA[BESR]]></category>
		<category><![CDATA[DH55PJ]]></category>
		<category><![CDATA[Exec]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[Recovery]]></category>
		<category><![CDATA[Symantec]]></category>
		<category><![CDATA[System]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=357</guid>
		<description><![CDATA[<p>Problema: Usando il disco di ripristino di Symantec Backup Exec System Recovery 2010 (BESR 2010), non viene riconosciuta la scheda di rete integrata sulla scheda madre (ad esempio: Intel DH55PJ &#8211; NIC 82578DC). Spiegazione: Il CD di ripristino contiene un numero limitato di driver di rete. Comunque è possibile aggiungerne di nuovi e/o più recenti, sempre [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Alessandro Spiandore <a href="http://www.ilcomputer.com/wordpress/2011/04/12/aggiungere-network-driver-su-symantec-backup-exec-system-recovery-besr/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2011/04/12/aggiungere-network-driver-su-symantec-backup-exec-system-recovery-besr/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Intel Raid Web Console 2 error: please select a host from the list</title>
		<link>http://www.ilcomputer.com/wordpress/2009/09/03/intel-raid-web-console-2-error-please-select-a-host-from-the-list/</link>
		<comments>http://www.ilcomputer.com/wordpress/2009/09/03/intel-raid-web-console-2-error-please-select-a-host-from-the-list/#comments</comments>
		<pubDate>Thu, 03 Sep 2009 19:44:55 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[software]]></category>
		<category><![CDATA[2008]]></category>
		<category><![CDATA[Console]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[please select a host from the list]]></category>
		<category><![CDATA[raid]]></category>
		<category><![CDATA[Server]]></category>
		<category><![CDATA[Web]]></category>
		<category><![CDATA[Windows]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=146</guid>
		<description><![CDATA[<p>Problema: Dopo aver installato su di un server Intel (dotato di controller RAID Intel/LSI) il software di controllo sotto Windows (nel mio caso Windows 2008 Standard Server) non si riesce ad entrare nella console di gestione in nessuna maniera in quanto appare sempre il seguente messaggio: &#8220;Please select a host from the list&#8221;. Soluzione: Disabilitare [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/software/">software</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2009/09/03/intel-raid-web-console-2-error-please-select-a-host-from-the-list/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2009/09/03/intel-raid-web-console-2-error-please-select-a-host-from-the-list/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Come t&#8217;installo il server: INTEL S5520HC (install guide)</title>
		<link>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallo-il-server-intel-s5520hc-install-guide/</link>
		<comments>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallo-il-server-intel-s5520hc-install-guide/#comments</comments>
		<pubDate>Fri, 21 Aug 2009 15:28:16 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[guida]]></category>
		<category><![CDATA[guide]]></category>
		<category><![CDATA[install]]></category>
		<category><![CDATA[installazione]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[S5520HC]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=133</guid>
		<description><![CDATA[<p>Aggiornato al 06 Luglio 2010 &#8211; Parte firmware: &#8211; http://www.intel.com/support/motherboards/server/s5520hc/index.htm &#8211; support main page -          Utilizzando la modalità EFI (da settare il boot in Internal EFI come primario, quindi “map –r” e dopo “fs0:” per vedere la chiavetta USB. Alla fine” startup.nsh” -          Seguire lo schema di aggiornamento firmware proposto: BMC v00.53 (aggiorna anche Remote [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallo-il-server-intel-s5520hc-install-guide/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallo-il-server-intel-s5520hc-install-guide/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Come t&#8217;installo il server: INTEL S5000PSLROMB (install guide)</title>
		<link>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallallo-s5000psl/</link>
		<comments>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallallo-s5000psl/#comments</comments>
		<pubDate>Fri, 21 Aug 2009 15:22:05 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[guida]]></category>
		<category><![CDATA[guide]]></category>
		<category><![CDATA[install]]></category>
		<category><![CDATA[installazione]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[S5000PSLROMB]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=127</guid>
		<description><![CDATA[<p>Parte firmware: &#8211; http://support.intel.com/support/motherboards/server/s5000psl/index.htm &#8211; support main page &#8211; Intel® Deployment Assistant ISO Image &#8211; CD Build Per aggiornare BIOS, BMC e FRUDSR come da ultimo pack disponibile in internet &#8211; Intel® RAID Controller SRCSAS18E &#8211; controllare firmware controller Raid (ROMB CARD SRCSAS18E) &#8211; Intel® Local Control Panel Firmware Update for DOS &#8211; controllare il [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallallo-s5000psl/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2009/08/21/come-tinstallallo-s5000psl/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Intel Remote Managment Module 3 &#8211; AXXRMM3 Error Java</title>
		<link>http://www.ilcomputer.com/wordpress/2009/07/20/intel-remote-managment-module-3-axxrmm3-error-java/</link>
		<comments>http://www.ilcomputer.com/wordpress/2009/07/20/intel-remote-managment-module-3-axxrmm3-error-java/#comments</comments>
		<pubDate>Mon, 20 Jul 2009 22:42:34 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[software]]></category>
		<category><![CDATA[AXXRMM3]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[Java]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=119</guid>
		<description><![CDATA[<p>Per chi, lanciando il controllo remoto, ottiene questo bell&#8217;errore: BadFieldException[ Abilitare la cache per il supporto nativelib o installer-desc,https://192.168.1.39/Java/release/Win32.jar] at com.sun.javaws.jnl.XMLFormat.handleResourceElement(Unknown Source) at com.sun.javaws.jnl.XMLFormat.access$800(Unknown Source) at com.sun.javaws.jnl.XMLFormat$2$1.visitElement(Unknown Source) at com.sun.javaws.jnl.XMLUtils.visitChildrenElements(Unknown Source) at com.sun.javaws.jnl.XMLFormat$2.visitElement(Unknown Source) at com.sun.javaws.jnl.XMLUtils.visitElements(Unknown Source) at com.sun.javaws.jnl.XMLFormat.buildResourcesDesc(Unknown Source) at com.sun.javaws.jnl.XMLFormat.parse(Unknown Source) at com.sun.javaws.jnl.LaunchDescFactory.buildDescriptor(Unknown Source) at com.sun.javaws.jnl.LaunchDescFactory.buildDescriptor(Unknown Source) at com.sun.javaws.jnl.LaunchDescFactory.buildDescriptor(Unknown Source) at com.sun.javaws.Main.launchApp(Unknown Source) [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2009/07/20/intel-remote-managment-module-3-axxrmm3-error-java/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2009/07/20/intel-remote-managment-module-3-axxrmm3-error-java/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Extensible Firmware Interface (EFI) &#8211; Basic operating instructions</title>
		<link>http://www.ilcomputer.com/wordpress/2008/12/01/extensible-firmware-interface-efi-basic-operating-instructions/</link>
		<comments>http://www.ilcomputer.com/wordpress/2008/12/01/extensible-firmware-interface-efi-basic-operating-instructions/#comments</comments>
		<pubDate>Mon, 01 Dec 2008 21:21:30 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[Basic]]></category>
		<category><![CDATA[command]]></category>
		<category><![CDATA[EFI]]></category>
		<category><![CDATA[Extensibile]]></category>
		<category><![CDATA[firmware]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[Interface]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/?p=63</guid>
		<description><![CDATA[<p>Come da titolo il link diretto al documento sul sito Intel delle istruzioni di programmazione ed utilizzo dell&#8217;interfaccia EFI di Intel: http://www.intel.com/support/motherboards/server/sb/CS-028743.htm</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2008/12/01/extensible-firmware-interface-efi-basic-operating-instructions/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2008/12/01/extensible-firmware-interface-efi-basic-operating-instructions/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Caricamento Driver Intel Matrix via floppy USB</title>
		<link>http://www.ilcomputer.com/wordpress/2007/10/22/caricamento-driver-intel-matrix-via-floppy-usb/</link>
		<comments>http://www.ilcomputer.com/wordpress/2007/10/22/caricamento-driver-intel-matrix-via-floppy-usb/#comments</comments>
		<pubDate>Mon, 22 Oct 2007 16:11:41 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[software]]></category>
		<category><![CDATA[.inf]]></category>
		<category><![CDATA[a:]]></category>
		<category><![CDATA[disk]]></category>
		<category><![CDATA[drive]]></category>
		<category><![CDATA[Driver]]></category>
		<category><![CDATA[floppy]]></category>
		<category><![CDATA[incompatibilitÃ ]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[IOMEGA]]></category>
		<category><![CDATA[Manager]]></category>
		<category><![CDATA[Matrix]]></category>
		<category><![CDATA[SONY]]></category>
		<category><![CDATA[Storage]]></category>
		<category><![CDATA[TEAC]]></category>
		<category><![CDATA[USB]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/2007/10/22/caricamento-driver-intel-matrix-via-floppy-usb/</guid>
		<description><![CDATA[<p>I driver Intel Matrix che vengono forniti durante la fase di setup di un sistema operativo possono essere caricati anche tramite lettore floppy USB a patto di disabilitare un eventuale controller floppy integrato sulla scheda madre, altrimenti la fase di startup continuerà  a domandare di caricare un fantomatico &#8220;Intel Matrix Storage Manager Driver&#8221; disk sul [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2007/10/22/caricamento-driver-intel-matrix-via-floppy-usb/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2007/10/22/caricamento-driver-intel-matrix-via-floppy-usb/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
		<item>
		<title>Probabile incompatibilitÃ  Hard Disk Western Digital RE2 500GB (WD5000YS).</title>
		<link>http://www.ilcomputer.com/wordpress/2007/05/05/probabile-incompatilita-hard-disk-western-digital-re2-500gb-wd5000ys/</link>
		<comments>http://www.ilcomputer.com/wordpress/2007/05/05/probabile-incompatilita-hard-disk-western-digital-re2-500gb-wd5000ys/#comments</comments>
		<pubDate>Sat, 05 May 2007 00:08:47 +0000</pubDate>
		<dc:creator>Spiandore Alessandro</dc:creator>
				<category><![CDATA[hardware]]></category>
		<category><![CDATA[Hard disk]]></category>
		<category><![CDATA[Intel]]></category>
		<category><![CDATA[raid]]></category>
		<category><![CDATA[raid5]]></category>
		<category><![CDATA[RE2]]></category>
		<category><![CDATA[sata]]></category>
		<category><![CDATA[SRCSAS144E]]></category>
		<category><![CDATA[SRCSAS18E]]></category>
		<category><![CDATA[SROMBSAS18E]]></category>
		<category><![CDATA[WD5000YS]]></category>
		<category><![CDATA[Western Digital]]></category>

		<guid isPermaLink="false">http://www.ilcomputer.com/wordpress/2007/05/05/probabile-incompatilita-hard-disk-western-digital-re2-500gb-wd5000ys/</guid>
		<description><![CDATA[<p>Dopo lunghi test e prove sono giunto alla conclusione che gli Hard Disk Western Digital RE2 500GB SATA-II non sono compatibili con i controller raid INTEL SRCSAS18E, SRCSAS144E e SROMBSAS18E. Il problema si presenta giÃ  in fase d&#8217;inizializzazione del virtual disk (Slow Initialization), interrompendo la stessa e mandando in FAIL i dischi del RAID 5. [...]</p>
<div style="display:block"><small><em>posted in <a href="http://www.ilcomputer.com/wordpress/category/hardware/">hardware</a> by Spiandore Alessandro <a href="http://www.ilcomputer.com/wordpress/2007/05/05/probabile-incompatilita-hard-disk-western-digital-re2-500gb-wd5000ys/#comments">Leave A Comment</a><br />&copy;2012 <a href="http://www.ilcomputer.com/wordpress">IL COMPUTER BLOG</a>. All Rights Reserved.</em></small></div>]]></description>
		<wfw:commentRss>http://www.ilcomputer.com/wordpress/2007/05/05/probabile-incompatilita-hard-disk-western-digital-re2-500gb-wd5000ys/feed/</wfw:commentRss>
		<slash:comments>0</slash:comments>
		</item>
	</channel>
</rss>

